Advanced Technology
High Quality
Sincere Service |
| |
- Reliability Qualification Services
|
| GUC offers proven and well defined reliability
assurance and qualification test services. It includes component
level qualification and board-level qualification, which refers
to JESD, EIAJ, MIL-STD and IPC standards. |
| |
- Reliability Qualification Services –Component
Level
|
| |
| Test Item |
Duration / Cycles |
Conditions |
|
| HTOL |
1000
hrs |
125℃/1000hrs/Vddmax |
| ESD |
|
HBM > 2KV;MM > 200V;CDM>100,200,1000,2000V |
| Latch
up |
|
|TV|>=1.5V
or |TC|>=100mA(Vdd,max / Room temp.) |
| BLT |
1000
hrs |
125℃/1000hrs/Vddmax |
| THB |
1000
cycles |
85℃/85%RH |
| TCT |
1000
cycles |
-65℃(10min)
-->(50secs) --> 150℃(10min) |
| TST |
100
cycles |
-65℃(5min)
-->(3secs) --> 150℃(5min) |
| HAST |
100
hrs |
135℃/85%RH |
| HTST |
1000
hrs |
150℃ |
| LTST |
1000
hrs |
-50℃ |
| THST |
1000
hrs |
85℃/85%RH |
| THCT |
10
cycles |
-10℃~65℃
/ 95%RH |
| MST |
Special
condition |
30℃ / 60%/
192hrs |
| Remark |
Test
will be done by reliability test partners (IST, Gtti,
Ma-tek, and packaging house) |
| Precondition
test profile follow JEDEC standard |
| |
|
|
| |
|
| |
 |
| |
- Reliability Qualification Services – Board
Level
|
| GUC provides Board Level qualification Services
to turnkey customer. Board-level qualification plan includes
JESD, EIAJ, and IPC standard. Based on customer’s special requirements,
GUC can provide customized qualification services. |
| |
|